RDN Model
Endovascular
HEARTROID RDN model allows trainees to understand how to manipulate catheters during RDN (renal denervation) procedure with or without X-ray fluoroscopy.
With a pulsatile pump included in the set, blood flow from the aorta to the extremity can be simulated and verified by realistic angiographic imaging.

We offer steeply angled renal branches, along with further customization depending on usage.
- Components -
RDN Model

Vessel Model for RDN
The model is primarily designed for RDN (renal denervation). Vessel model can be customized depending on the purpose of use, along with the special tank.

Special Tank for RDN
Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than six liters of water are required for training.

Pulsatile Pump Type1
Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1200-4800ml/min in flow volume.). Realistic X-ray images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.

Tubes with Sheath
Special tubes with sheath.
Number of tubes: 2( 8Fr )

Lubricant
Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )

Hoses
Hose with one-touch joint.

Camera Set
A compact camera with a flexible arm that can provide clear images from various angles.

Damage Protection Case (L)
Capable of containing the whole components.
BoxCaseTrunk.
Capable of containing the components.Detuchable casters (spare casters include).
- Components -
RDN Model

Vessel Model for RDN
The model is primarily designed for RDN (renal denervation). Vessel model can be customized depending on the purpose of use, along with the special tank.

Special Tank for RDN
Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than six liters of water are required for training.

Pulsatile Pump Type1
Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1200-4800ml/min in flow volume.). Realistic X-ray images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.

Tubes with Sheath
Special tubes with sheath.
Number of tubes: 2( 8Fr )

Lubricant
Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )

Hoses
Hose with one-touch joint.

Camera Set
A compact camera with a flexible arm that can provide clear images from various angles.

Damage Protection Case (L)